Transformers for medical technology

DESCRIPTION

Medical systems must safely comply with the leakage currents required by the standard. The TÜV-tested REOMED I isolating transformers are tried and tested devices for use in all electrical systems in medical rooms - they limit the leakage current and thus help to ensure the safety of the operator and patient. In addition to very good efficiency and simple connection options, the REOMED I isolating transformers are characterized by a very low magnetic stray field and a high level of safety. Depending on the model and customer requirements, the isolating transformers can be equipped with electronic switch-on damping, overvoltage protection and a line filter.

BENEFITS

  • wide range of options
  • light weight
  • Short circuit and overload protection
  • integrated inrush current limitation
  • stable aluminum housing
  • Equipotential bonding pin according to DIN 42801
  • Plug connections according to IEC 60320
  • IEC 60601-1: 2005 / AMD1: 2012
    ANSI / AAMIES 60601-1: 2005 / CR / 2012
    CAN / CSA C22.2 No.60601-1: 14 (medical technology) USA and Canada
    IEC 60601-1-2: 2014 ( Partly); EN / IEC 61000-3-2: 2014; EN / IEC 61000-3-3: 2013

* With rubber feet

Technical specification

ISOLATION TRANSFORMER REOMED I 1600

DIMENSIONS IN MM

DIMENSIONS IN MM

Suitable for this product


HOUSING AND INTERFERENCE SUPPRESSION TRANSFORMER

A damping of up to 90 dB is achieved with specially wound isolating transformers in segregated windings due to the low-capacitance design and an additional high-quality filter.

ISOLATION TRANSFORMER REOMED I 300

Medical systems must safely comply with the leakage currents required by the standard. The TÜV-tested REOMED I isolating transformers are tried and tested devices for use in all electrical systems in medical rooms - they limit the leakage current and thus help to ensure the safety of the operator and patient. In addition to very good efficiency and simple connection options, the REOMED I isolating transformers are characterized by a very low magnetic stray field and a high level of safety. Depending on the model and customer requirements, the isolating transformers can be equipped with electronic switch-on damping, overvoltage protection and a line filter.

LEAKAGE TRANSFORMER RUT 500

In railway applications, where it‘s about the greatest possible comfort and safety of passengers, components are required that save space, are safe and have a long service life.