uk
Transportation Converter Solutions

Transportation Converter Solutions

SAFE AND STANDARDISED PRODUCTS FOR RAILWAY ENGINEERING

The safety of passengers and the compliance of railway standards is of the utmost importance in this market. Most applications demand that components must be adapted to the local environmental and operating conditions. High quality standards and continuous developments ensure that that REO is a reliable partner within this sector.

To guarantee compliance with railway norms, standards and the classification of Ingress Protection the following methods are used:

  • In-house testing laboratories
  • Shock and vibration tests
  • Cooperation only with selected suppliers
  • FEM analysis for the simulation of environmental influences


For railway technology REO offers inter alia:

  • NTT BW – Braking, smoothing and filter resistors
  • NTT – Mains chokes, motor chokes, interference chokes, absorption circuit choke, EMC chokes, dv/dt chokes, AC/DC chokes
  • RFI filter, sinusoidal filter, harmonic filter
  • NUT – inverter transformers AC transformers, power transformer, HF transformer, current transformer, special components for energy generation
  • NPT – test chokes for load test of frequency converters
  • REOLAB mobil – mobile power supply for the railway workshop
  • REOLAB – test devices for duration and function tests

All components for the railway technology - from transformers and chokes up to filters - are developed as a standard design or in accordance with the specific requirements of our customers. Without this specific, essential requirements, no product can operate:

  • Safety: to ensure that the safety and comfort of passengers are not impaired, every component used in a train must meet the current norms and standards. Own tests and accredited testing laboratories prove the safety of our components. 
  • Weight: Intelligent methods in materials selection and FEM-calculation mean that REO components are of particularly low weight. 
  • Space : The optimal use of space, and compliance with specified mechanical and electrical requirements, form the basis of our development work. 
  • Costs: With the latest software, simulation and testing techniques, we ensure that the necessary development work is already optimally used in advance. 
  • Series IN-B

    Bushing-type and bar-type current transformers

    Series IN-B
    • Primary rated current: 600 A
    • Max. Primärnennstrom: 720
    • Sekundärstrom: 300 A

    For the high demands of railway and industrial engineering at higher frequencies up to 50kHz. High-quality nanocrystalline core materials guarantee the greatest degree of transmission quality and low losses.


    Exclusive use of UL-listed materials, fully sealed with UL94-V0 material. Current transformers for demanding applications, such as in the railway sector and general transportation sectors. Robust housing construction with reliable securing options for vertical or horizontal mounting.



    • According to: EN/IEC 61869-1/2

    • Primary rated current: 600 A

    • Frequency range: 50 - 50.000 Hz



    Application area



    • Industry

    • Railway engineering



  • NTT 400 U

    Onboard power supply transformer (Underfloor housing)

    NTT 400 U
    • Rated power: 10000 - 30000 VA
    • Input voltage: 3x440 V

    The REO transformer NTT 400 U is designed for on-board power supplies, which are fed by the auxiliary converter.The transformer NTT 400 U is the complete, ready to use-unit with transformer and housing. It is used to adjust the voltage and for galvanic separation of pulse-width modulated DC link voltage and the consumers of the electrical system. A corresponding sinusoidal filter must be connected between the transformer and the inverter.


    The secondary-side load of the isolation transformer can be switchgears, rotating equipment , resistive loads or semiconductor power converters.The transformers are designed for the use in vehicles with AC or DC power (in inverter mode). This guarantees that REO transformers are optimally suited to your application. Our development methods emphasize maximum useful lifetime, cost/benefit optimization and safety.



    • Power. 10 - 30 kVA


    • Rated voltage


      Primary:
      Rated voltage: (Normal operation): 3x440 Veff 60 Hz
      Rated voltage: (external power supply): 3x400 Veff 50 Hz
      Rated voltage: (reduced operation): 3x345 Veff 47 Hz


      Secondary:
      Voltage: 3x230 Veff



    • Insulation class: F/H

    • Test voltage: EN 50124 / EN 60310

    • Operating temperature:  -40°C ... +55°C (optional +75°C)

    • Humidity: max. 95%

    • Pollution: PD 4

    • Vibration resistance: Cat.1 class A/B acc. to EN61373

    • Voltages: 24 / 42 / 110 / 230 / 400 / 690 Volt (Optional)

    • Switching group: Optional


     


    Customer-specific components


    Onboard power supply transformer can be custom designed. Are you interested in this product? Please contact us!


    Besides the standard components for use in the converter, REO offers customerspecific products - as individual components or as a complete solution in a ontainer. The most important criteria in railway engineering are availability for operation and passenger safety. Here, REO offers customized solutions that we develop step by step in close cooperation with our client. 

  • NTT 400 D

    Onboard power supply transformer (Roof mounted)

    NTT 400 D
    • Rated power: 10000 - 30000 VA
    • Input voltage: 3x440 V

    The REO transformer NTT 400 D is designed for on-board power supplies, which are fed by the auxiliary converter.The transformer NTT 400 D is the complete, ready to use-unit with transformer, mounting frame and housing. It is used to adjust the voltage and for galvanic separation of pulse-width modulated DC link voltage and the consumers of the electrical system. A corresponding sinusoidal filter must be connected between the transformer and the inverter.


    The secondary-side load of the isolation transformer can be switchgears, rotating equipment , resistive loads or semiconductor power converters.The transformers are designed for the use in vehicles with AC or DC power (in inverter mode). This guarantees that REO transformers are optimally suited to your application. Our development methods emphasize maximum useful lifetime, cost/benefit optimization and safety.



    • Power. 10 - 30 kVA


    • Rated voltage


      Primary:
      Rated voltage: (Normal operation): 3x440 Veff 60 Hz
      Rated voltage: (external power supply): 3x400 Veff 50 Hz
      Rated voltage: (reduced operation): 3x345 Veff 47 Hz


      Secondary:
      Voltage: 3x230 Veff



    • Insulation class: F/H

    • Test voltage: EN 50124 / EN 60310

    • Operating temperature:  -40°C ... +55°C (optional +75°C)

    • Humidity: max. 95%

    • Pollution: PD 4

    • Vibration resistance: Cat.1 class A/B acc. to EN61373

    • Voltages: 24 / 42 / 110 / 230 / 400 / 690 Volt (Optional)

    • Switching group: Optional


     


    Customer-specific components


    Onboard power supply transformer can be custom designed. Are you interested in this product? Please contact us!


    Besides the standard components for use in the converter, REO offers customerspecific products - as individual components or as a complete solution in a ontainer. The most important criteria in railway engineering are availability for operation and passenger safety. Here, REO offers customized solutions that we develop step by step in close cooperation with our client. 

  1. Page:
  2. 1
  3. 2
  4. 3

Downloads

  • Download
    Protection Ratings
    pdf 4.00 KB

    Protection Ratings

    Discover our brochure about high protection ratings!
    Download
  • Download
    REO Leakage field transformer
    pdf 4.00 KB

    REO Leakage field transformer

    REO Leakage field transformer
    Download
  • Download
    Liquid cooled systems catalog
    pdf 4.00 KB

    Liquid cooled systems catalog

    Product catalog for liquid cooled systems
    Download
  • Download
    Air chokes catalogue
    pdf 4.00 KB

    Air chokes catalogue

    Product catalogue REO air chokes
    Download
  • Download
    Components for railway applications catalogue
    pdf 4.00 KB

    Components for railway applications catalogue

    Product catalogue: REO components for railway applications
    Download
  • Download
    Questionnaire water cooling
    pdf 4.00 KB

    Questionnaire water cooling

    Questionnaire water cooling
    Download