DV/Dt - Chokes/Filter

Cost-effective solution for minimizing the dv / dt rise
REO dv/dt chokes and filters attenuate due to their structure the voltage rise to acceptable values .
For short cable lengths between inverter and motor a dv/dt choke limits the increase speed to less than 1000 V/μs, which is sufficient for most motors and standards.
-
CNW 806
Three-phase-dv/dt filter
- Nominal Voltage: 500 V
- Rated current: 4 - 1200 A
- Inductance: 0,005 - 1,5 mH
Reduce voltage rice to < 500V/µs - electrical consumrs and insulation will protected with low costs.
A simple and inexpensive method for reducing the rate of voltage rise is to use a du / dt filter or throttle. It dampens the voltage rise to acceptable values and prevents overvoltages on long supply lines.
Losses and heating are minimized and the leakage current reduced. By limiting the rate of voltage rise, the motor insulation is protected and thus prolongs the life.
Also, the electromagnetic interference can be reduced in the radiation range of 1 MHz to 30 MHz.
- Rated voltage: U ≤ 3 x 500 V
- Reduce voltage rice to < 500V/µs
- Field frequency: 0 - 60 Hz
- Drive switching frequency: up to 150 A >4kHz, from 150 A >1,5KHz
- According to: EN 60289 / EN 61558
- Test voltage: L-L 2500 V, AC/50Hz 60s; L-PE 2500 V, AC/50Hz 60s
- Insulation class: T40/F
- Protection rating: IP00
- Climatic categorie: DIN IEC 60068-1
- Overload: 1,5 x INenn 1 min / h
- Ambient temperature: 40 °C
- Design: standing on foot angle
Typical applications
- Drive systems for motor drives:
- Mechanical engineering
- Elevators / escalators
- Pipes
- Conveyor technology
- Ventilation and air conditioning
- Robotics
- Automation technology
- Power supplies
- Wind turbines
-
CNW M 833
Fully encapsulated three-phase dv/dt Filter (IP20)
- Nominal Voltage: 400 V
- Rated current: 8 - 175 A
- Inductance: 0,09 - 2 mH
Reduce voltage rice to < 500V/µs - electrical consumrs and insulation will protected with low costs.
A simple and inexpensive method for reducing the rate of voltage rise is to use a du / dt filter. The filter attenuates the voltage rise to acceptable values and prevents overvoltages on long supply lines. Losses and heating are minimized and reduces the leakage current. By limiting the rate of voltage rise, the motor insulation is protected and thus increases the service life.
Also, the electromagnetic interference can be reduced in the radiation range of 1 MHz to 30 MHz.
Voltage risers is reduced to < 500V/µs.
- Rated voltage: U ≤ 3 x 400 V
- Reduce the voltage rise dv / dt to < 500V/µs
- Max. cable length to the motor: 200 m
- Field frequency: 10 - 60 Hz
- Short circuit voltage at 400 V: 0.8%
- Drive switching frequency: 4 kHz > ft < 8 kHz
- According to: EN 60289 / EN 61558
- Test voltage: L-L 2500 V, AC/50Hz 60s; L-PE 2500 V, AC/50Hz 60s
- Insulation class: T40/F
- Protection rating: IP20
- Climatic categorie: DIN IEC 60068-1
- Overload: 1,5 x INenn 1 min / h
- Ambient temperature: 40 °C
- Design: standing on foot angle
Typical applications
- Drive systems for motor drives:
- Mechanical engineering
- Elevators / escalators
- Pipes
- Conveyor technology
- Ventilation and air conditioning
- Robotics
- Automation technology
- Power supplies
- Wind turbines
-
CNW M 833
Fully encapsulated three-phase dv/dt Filter (IP54)
- Nominal Voltage: 400 V
- Rated current: 8 - 175 A
- Inductance: 0,09 - 2 mH
Reduce voltage rice to < 500V/µs - electrical consumrs and insulation will protected with low costs.
The dv / dt filters in fully encapsulated version are specially designed for rough environments and offer a very good mechanical protection of the component. The fully encapsulation allows design up to protection ratings IP 66.
The filter attenuates the voltage rise to acceptable values and prevents overvoltages on long supply lines. Losses and heating are minimized and reduces the leakage current. By limiting the rate of voltage rise, the motor insulation is protected and thus increases the service life.
Also, the electromagnetic interference can be reduced in the radiation range of 1 MHz to 30 MHz.
Voltage risers is reduced to < 500V/µs.
- Rated voltage: U ≤ 3 x 400 V
- Reduce the voltage rise dv / dt to < 500V/µs
- Max. cable length to the motor: 200 m
- Field frequency: 10 - 60 Hz
- Short circuit voltage at 400 V: 0.8%
- Drive switching frequency: 4 kHz > ft < 8 kHz
- According to: EN 60289 / EN 61558
- Test voltage: L-L 2500 V, AC/50Hz 60s; L-PE 2500 V, AC/50Hz 60s
- Insulation class: T40/F
- Protection rating: IP20
- Climatic categorie: DIN IEC 60068-1
- Overload: 1,5 x INenn 1 min / h
- Ambient temperature: 40 °C
- Design: standing on foot angle
Typical applications
- Drive systems for motor drives:
- Mechanical engineering
- Elevators / escalators
- Pipes
- Conveyor technology
- Ventilation and air conditioning
- Robotics
- Automation technology
- Power supplies
- Wind turbines