EMC-Filter
No line-conducted interferences due to the EMC filter
EMC filters are used for suppressing line-conducted interferences.
The spreading is prevented by a maximum level of impedance mismatch. The filtering effect extends in both directions. This means that both the interference from the consumer to the network and the interference from the network to the consumer are suppressed.
-
CNW 101
Single-phase mains filters (2 lines, single-stage)
- Nominal Voltage: 250 V
- Rated current: 3 - 20 A
Applications: Switch-mode power supplies for industrial electronics, telecommunications, data systems engineering and DC applications.
- Conforming to: VDE 0565-3 / IEC 950 / UL 1283
- Test voltage: L-N 2100 V, DC 1s, L/N-PE 2700 V, DC 1s
- Overload: 1,5 x I 1 min/h
- Climatic category: DIN IEC 68 Teil 1 25/085/21
-
CNW 102
Single-phase mains filters (2 lines, two-stages)
- Nominal Voltage: 250 V
- Rated current: 3 - 20 A
Applications: Switch-mode power supplies for industrial electronics, frequency converters for motor drives, power supply units, medical and telecommunication applications, DC applications
- Conforming to: VDE 0565-3 / IEC 950 / UL 1283
- Test voltage: L-N 2100 V, DC 1s, L/N-PE 2700 V, DC 1s
- Overload: 1,5 x I 1 min/h
- Climatic category: DIN IEC 68 Teil 1 25/085/21
-
CNW 103
Three-phase mains filters (3 lines, single-stage)
- Nominal Voltage: 480 V
- Rated current: 3 - 150 A
Applications: Frequency converters for motor drives (e.g. lifts, materials handling, pumps, ventilation and air-conditioning systems, industrial applications, wind power installations and power supply units- Conforming to: VDE 0565-3 / IEC 950 / UL 1283
- Test voltage: L-L 2100 V, DC 1s, L-PE 2700 V, DC 1s
- Overload: 1,5 x I 1 min/h
- Climatic category: DIN IEC 68 Teil 1 25/085/21
-
CNW 107.3/480
High-current mains filters (3 lines)
- Nominal Voltage: 480 V
- Rated current: 280 - 3000 A
Applications: Suppression of frequency inverters, Power electronics and general suppression for higher power ratings on wind energy and industrial applications.
- Conforming to: VDE 0565-3 / IEC 950 / UL 1283
- Test voltage: L-N 2100 V,DC 1s, L/N-PE 2700 V,DC 1s
- Overload: 1,5 x I 1 min/h
- Climatic category: DIN IEC 68 Teil 1 25/085/21
-
CNW 107.3/690
High-current mains filters (3 lines)
- Nominal Voltage: 690 V
- Rated current: 280 - 3000 A
Applications: Suppression of frequency inverters, Power electronics and general suppression for higher power ratings on wind energy and industrial applications.
- Conforming to: VDE 0565-3 / IEC 950 / UL 1283
- Test voltage: L-N 2100 V,DC 1s, L/N-PE 2700 V,DC 1s
- Overload: 1,5 x I 1 min/h
- Climatic category: DIN IEC 68 Teil 1 25/085/21
-
CNW 114/690
Three-phase mains filters (3 lines)
- Nominal Voltage: 690 V
- Rated current: 80 - 1200 A
Applications: Frequency converters for motor drives, wind power installations and power supply units
- Conforming to: VDE 0565-3 / IEC 950 / UL 1283
- Test voltage: L-L 2100 V, DC 1s, L-PE 2700 V, DC 1s
- Overload: 1,5 x I 1 min/h
- Climatic category: DIN IEC 68 Teil 1 25/085/21